| Wisdom Connects Everything, Enable Digitalization |
SUNPN Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen
Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen
In pharmaceutical, electronics and food cleanrooms, three readings decide whether the environment is under control: temperature, dew point and differential pressure. Temperature affects process stability, dew point reveals the true moisture load in the air, and differential pressure confirms that air flows from clean areas toward less clean areas — the foundation of contamination control.
The problem is that these three parameters are usually monitored by three separate instruments, read manually, and recorded even later. SUNPN's Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen consolidates all three onto one industrial LED panel — visible across the room, alarming the moment any value drifts, and feeding data into your Environment Monitoring System Panel in real time.
Product Overview
The is a wall-mounted Temperature, dew point, and differential pressure display screen with three rows of 3-inch high-brightness red LED digits:
- Temperature (°C) — range −20 to 100 °C
- Dew point temperature (°C)
- Differential pressure (Pa) — negative values supported, one-decimal resolution
Labels can be produced in English, Chinese or bilingual layout, with or without custom branding, so the panel reads clearly to every operator on the floor.


Key Specifications
|
Item |
Specification |
|
Product Model |
YWB00093 |
|
Display Content |
Temperature / Dew Point / Differential Pressure |
|
Display Material |
3-inch digital tube (red light) |
|
Panel Material |
Acrylic sheet + spray paint |
|
Frame Material |
Aluminum alloy frame (black) |
|
Dimensions |
640 × 430 × 50 mm |
|
Power Supply |
220 V, 1.8 m power cord, standard three-prong plug |
|
Data Storage |
Power-off data storage lasts up to 7 days |
|
Installation |
Wall-mounted |
|
Wiring |
Aviation plug at the top of the screen, network port wiring |
|
Communication |
TCP/IP and RS485 |
|
Accessories |
25-key remote control ×1, sound and light alarm ×1, temperature sensor ×1, differential pressure sensor ×1 |
Key Functions
1. Three Parameters, One Glance
Instead of walking the room with a thermometer and a manometer, staff see temperature, dew point and differential pressure simultaneously on one high-brightness panel. The 3-inch red digits are legible from meters away, even under cleanroom lighting.
2. Sound and Light Over-Limit Alarm
When any actual value falls below the lower limit or exceeds the upper limit, the panel triggers an audible and visual alert: the buzzer sounds intermittently, the top beacon flashes and the out-of-range value flashes on screen. If values stay within limits, the display stays quiet — so any alarm means "act now." Reminders can be cancelled via the remote control or host software without clearing the flashing data prompt.
3. Error Value Correction (±20.0)
Field calibration is built in: each value can be corrected within a ±20.0 range via remote controller or host software, so readings always match your reference instrument — no need to return the unit to the factory.
4. Remote Controller and Host Software Configuration
All settings — limits, correction values, reminder behavior — are set via the included 25-key remote control or through the host software. No ladder-and-laptop reprogramming every time a setpoint changes.
5. 7-Day Power-Off Data Storage
Even after a power interruption, stored settings and data are retained for up to 7 days, so the display returns to normal operation without reconfiguration.
6. TCP/IP and RS485 Communication
The board connects through the top aviation plug and network port wiring, supporting TCP/IP and RS485 protocols — the standard interfaces for BMS, SCADA and any Environment Monitoring System Panel.
System Architecture: From One Board to a Plant-Wide Network
A single display solves one room. SUNPN's architecture scales to the whole plant:
Environmental Data Boards → 200C Gateways → Local Area Network → Database Server / Software Client / LCD Terminal
The self-contained software system performs real-time monitoring and data collection of every device, with:
- A real-time monitoring dashboard for all boards across factory areas (temperature, humidity and alarm status at a glance)
- Abnormality data logs with timestamps — every out-of-range event recorded as it happens
- The OkMes background system for real-time monitoring and timely feedback: alarm records, device data records, historical records, exception frequency analysis and exportable reports
Suggested image: System architecture diagram (5-系统架构) and software dashboards (1-卖点_04 / 1-卖点_05). Alt text: "Cleanroom environmental monitoring displays connected through 200C gateways to OkMes monitoring software and LCD terminal"
This means the display is not just a local signboard — it is a data node in your quality system, producing the records auditors and customers ask for.
Typical Applications
|
Environment |
Why It Fits |
|
Pharmaceutical & GMP cleanrooms |
Pressure cascade verification plus temperature and dew point on one panel |
|
Electronics & semiconductor plants |
Moisture-sensitive process monitoring with dew point readout |
|
Food & beverage production |
Temperature and humidity-derived dew point control |
|
Laboratories & hospitals |
Differential pressure monitoring for isolation and sterile areas |
|
Paint booths & drying rooms |
Dew point control for coating quality |



How to Choose a Cleanroom Environmental Monitoring Display
Before you buy, check this list:
- Parameters — confirm temperature, dew point and differential pressure are shown together, and whether CO₂ or PM2.5 can be added later.
- Visibility — 3-inch or larger digits for reading across the room.
- Alarms — user-defined limits plus sounder and beacon output.
- Calibration — on-site error correction (e.g. ±20.0) without factory return.
- Communication — TCP/IP and RS485 for integration with your Environment Monitoring System Panel.
- Customization and support — a manufacturer that supports OEM/ODM and long-term project supply.
.jpg)
Why Choose SUNPN?
- Integrated three-parameter monitoring — temperature, dew point and differential pressure in one Cleanroom Environmental Monitoring Display
- Industrial build — aluminum alloy frame, acrylic panel, 7-day power-off storage
- Open communication — TCP/IP and RS485, ready for BMS/SCADA integration
- Complete system support — gateways, OkMes software, dashboards and reports included
- OEM/ODM customization — panel layout, labels, languages and display content tailored to your site
.jpg)
.jpg)
Frequently Asked Questions
Q1: What parameters does the display screen show?
Temperature (−20 to 100 °C), dew point temperature (°C) and differential pressure (Pa, one decimal, negative values supported) — all three simultaneously in 3-inch red LED digits.
Q2: How does the alarm work?
When a value exceeds your set upper/lower limits, the buzzer sounds intermittently, the top beacon light flashes and the out-of-range value flashes on the panel. The reminder can be cancelled by remote control or host software.
Q3: Can the readings be calibrated on site?
Yes. Each parameter supports an error correction range of ±20.0, set via remote controller or host software.
Q4: How does it connect to our Environment Monitoring System Panel?
Through TCP/IP and RS485 with network port wiring and a top aviation plug. Multiple boards can be networked via 200C gateways into the OkMes monitoring software for dashboards, alarm records and historical reports.
Q5: What happens after a power failure?
Settings and data are retained for up to 7 days, and the display resumes normal operation once power is restored.
Q6: Can the panel be customized?
Yes. Display content, label language (English/Chinese/bilingual), panel layout and branding can all be customized. Contact SUNPN with your requirements.
【20261105-XF】
| Product Size | Length: 640mm, Width: 430mm, Thickness: 50mm |
| Model No. | YWB00093 |
| Panel Material | Acrylic organic glass + inkjet printing |
| Frame Material | Black aluminum alloy outer frame |
| Display Material | 3-inch digital tube (red light) |
| Data Storage | Data retention for up to 7 days after power failure |
| Power Supply | 220V, 1.8m cable, national standard three-pin plug |
| Installation Method | Wall-mounted |
| Cable Outlet | Aviation connector and network port on upper left of the screen |
| Accessories | 25-key remote control *1, sound & light alarm *1, temperature sensor *1, differential pressure sensor *1 |
1. Three Critical Parameters, One Panel
Short claim: Temperature, dew point and differential pressure — monitored together, read at a glance.
Stop juggling separate thermometers and manometers. The YWB00093 shows all three cleanroom-critical parameters simultaneously in large 3-inch red LED digits — legible across the room, refreshed in real time, 24/7.
- Simultaneous display: temperature (−20~100 °C), dew point (°C), differential pressure (Pa, negative values supported)
- 3-inch high-brightness red digital tube, readable from meters away
- Aluminum alloy housing + acrylic panel, wall-mounted, 640 × 430 mm
- Bilingual (English/Chinese) or custom labels, OEM/ODM welcome
2. Alarms That Act, Calibration That Stays On Site
Short claim: Out-of-range in seconds, corrected in seconds — without a factory return.
Every parameter carries freely set upper and lower limits. When a value drifts, the buzzer sounds, the beacon flashes and the number flashes on screen — staff respond instantly. And with ±20.0 field error correction via remote control or host software, the readings always match your reference instrument.
- Sound-light alarm: intermittent buzzer + flashing beacon + flashing value
- ±20.0 error correction per parameter, set on site via 25-key remote or host software
- 7-day power-off data storage — settings survive outages, no reconfiguration
- Reminders cancellable remotely without clearing the flashing data prompt
3. Built to Connect — TCP/IP, RS485 and OkMes Integration
Short claim: Not just a signboard — a data node in your quality system.
With TCP/IP and RS485 over standard network port wiring, every reading flows into your BMS, SCADA or Environment Monitoring System Panel in real time. Scale from one room to the whole plant: boards networked through 200C gateways into the OkMes software for dashboards, alarm logs and exportable reports.
- TCP/IP + RS485 communication, aviation plug and network port wiring
- Plant-wide architecture: data boards → 200C gateways → LAN → database / software client / LCD terminal
- OkMes software: real-time dashboards, abnormality logs, historical records and reports
- Project supply support for multi-room and multi-site deployments