Wisdom Connects Everything, Enable Digitalization
Email Us
Call Us Now
about banner
  • Temperature, dew point, and differential pressure display screen
  • SUNPN Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen
  • SUNPN Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen
  • SUNPN Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen
  • SUNPN Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen
  • SUNPN Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen
  • SUNPN Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen

SUNPN Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen


Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen


In pharmaceutical, electronics and food cleanrooms, three readings decide whether the environment is under control: temperature, dew point and differential pressure. Temperature affects process stability, dew point reveals the true moisture load in the air, and differential pressure confirms that air flows from clean areas toward less clean areas — the foundation of contamination control.

The problem is that these three parameters are usually monitored by three separate instruments, read manually, and recorded even later. SUNPN's Cleanroom Temperature, Dew Point, and Differential Pressure Display Screen  consolidates all three onto one industrial LED panel — visible across the room, alarming the moment any value drifts, and feeding data into your Environment Monitoring System Panel in real time.




Product Overview

The  is a wall-mounted Temperature, dew point, and differential pressure display screen with three rows of 3-inch high-brightness red LED digits:

  • Temperature (°C) — range −20 to 100 °C
  • Dew point temperature (°C)
  • Differential pressure (Pa) — negative values supported, one-decimal resolution

Labels can be produced in English, Chinese or bilingual layout, with or without custom branding, so the panel reads clearly to every operator on the floor.
Temperature, dew point, and differential pressure display screen
Temperature, dew point, and differential pressure display screen features

 

Key Specifications

Item

Specification

Product Model

YWB00093

Display Content

Temperature / Dew Point / Differential Pressure

Display Material

3-inch digital tube (red light)

Panel Material

Acrylic sheet + spray paint

Frame Material

Aluminum alloy frame (black)

Dimensions

640 × 430 × 50 mm

Power Supply

220 V, 1.8 m power cord, standard three-prong plug

Data Storage

Power-off data storage lasts up to 7 days

Installation

Wall-mounted

Wiring

Aviation plug at the top of the screen, network port wiring

Communication

TCP/IP and RS485

Accessories

25-key remote control ×1, sound and light alarm ×1, temperature sensor ×1, differential pressure sensor ×1

Key Functions

1. Three Parameters, One Glance

Instead of walking the room with a thermometer and a manometer, staff see temperature, dew point and differential pressure simultaneously on one high-brightness panel. The 3-inch red digits are legible from meters away, even under cleanroom lighting.

2. Sound and Light Over-Limit Alarm

When any actual value falls below the lower limit or exceeds the upper limit, the panel triggers an audible and visual alert: the buzzer sounds intermittently, the top beacon flashes and the out-of-range value flashes on screen. If values stay within limits, the display stays quiet — so any alarm means "act now." Reminders can be cancelled via the remote control or host software without clearing the flashing data prompt.

3. Error Value Correction (±20.0)

Field calibration is built in: each value can be corrected within a ±20.0 range via remote controller or host software, so readings always match your reference instrument — no need to return the unit to the factory.

4. Remote Controller and Host Software Configuration

All settings — limits, correction values, reminder behavior — are set via the included 25-key remote control or through the host software. No ladder-and-laptop reprogramming every time a setpoint changes.

5. 7-Day Power-Off Data Storage

Even after a power interruption, stored settings and data are retained for up to 7 days, so the display returns to normal operation without reconfiguration.

6. TCP/IP and RS485 Communication

The board connects through the top aviation plug and network port wiring, supporting TCP/IP and RS485 protocols — the standard interfaces for BMS, SCADA and any Environment Monitoring System Panel.

Cleanroom environmental monitoring display with sound-light alarm, TCP/IP and RS485 communication
Environment Monitoring System Panel

System Architecture: From One Board to a Plant-Wide Network

A single display solves one room. SUNPN's architecture scales to the whole plant:

Environmental Data Boards → 200C Gateways → Local Area Network → Database Server / Software Client / LCD Terminal

The self-contained software system performs real-time monitoring and data collection of every device, with:

  • A real-time monitoring dashboard for all boards across factory areas (temperature, humidity and alarm status at a glance)
  • Abnormality data logs with timestamps — every out-of-range event recorded as it happens
  • The OkMes background system for real-time monitoring and timely feedback: alarm records, device data records, historical records, exception frequency analysis and exportable reports

Suggested image: System architecture diagram (5-系统架构) and software dashboards (1-卖点_04 / 1-卖点_05). Alt text: "Cleanroom environmental monitoring displays connected through 200C gateways to OkMes monitoring software and LCD terminal"

This means the display is not just a local signboard — it is a data node in your quality system, producing the records auditors and customers ask for.

Typical Applications

Environment

Why It Fits

Pharmaceutical & GMP cleanrooms

Pressure cascade verification plus temperature and dew point on one panel

Electronics & semiconductor plants

Moisture-sensitive process monitoring with dew point readout

Food & beverage production

Temperature and humidity-derived dew point control

Laboratories & hospitals

Differential pressure monitoring for isolation and sterile areas

Paint booths & drying rooms

Dew point control for coating quality


"Industrial LED dew point display screen with aluminum alloy housing and acrylic panel, top and side view
Real shot of temperature, dew point, and pressure difference display screen
Side view of the temperature, dew point, and pressure difference display screen
Environmental monitoring system architecture

How to Choose a Cleanroom Environmental Monitoring Display

Before you buy, check this list:

  1. Parameters — confirm temperature, dew point and differential pressure are shown together, and whether CO₂ or PM2.5 can be added later.
  2. Visibility — 3-inch or larger digits for reading across the room.
  3. Alarms — user-defined limits plus sounder and beacon output.
  4. Calibration — on-site error correction (e.g. ±20.0) without factory return.
  5. Communication — TCP/IP and RS485 for integration with your Environment Monitoring System Panel.
  6. Customization and support — a manufacturer that supports OEM/ODM and long-term project supply.
Recommended products related to environmental monitoring systems
Recommended selection of environmental monitoring dashboards

Why Choose SUNPN?

  • Integrated three-parameter monitoring — temperature, dew point and differential pressure in one Cleanroom Environmental Monitoring Display
  • Industrial build — aluminum alloy frame, acrylic panel, 7-day power-off storage
  • Open communication — TCP/IP and RS485, ready for BMS/SCADA integration
  • Complete system support — gateways, OkMes software, dashboards and reports included
  • OEM/ODM customization — panel layout, labels, languages and display content tailored to your site
Environmental monitoring dashboard application cases
Application Cases of Temperature, Humidity and Dew Point Kanban
Application Cases of Temperature, Humidity and Pressure Difference Display Screens

Frequently Asked Questions

Q1: What parameters does the display screen show?
Temperature (−20 to 100 °C), dew point temperature (°C) and differential pressure (Pa, one decimal, negative values supported) — all three simultaneously in 3-inch red LED digits.

 

Q2: How does the alarm work?
When a value exceeds your set upper/lower limits, the buzzer sounds intermittently, the top beacon light flashes and the out-of-range value flashes on the panel. The reminder can be cancelled by remote control or host software.

 

Q3: Can the readings be calibrated on site?
Yes. Each parameter supports an error correction range of ±20.0, set via remote controller or host software.

 

Q4: How does it connect to our Environment Monitoring System Panel?
Through TCP/IP and RS485 with network port wiring and a top aviation plug. Multiple boards can be networked via 200C gateways into the OkMes monitoring software for dashboards, alarm records and historical reports.

 

Q5: What happens after a power failure?
Settings and data are retained for up to 7 days, and the display resumes normal operation once power is restored.

 

Q6: Can the panel be customized?
Yes. Display content, label language (English/Chinese/bilingual), panel layout and branding can all be customized. Contact SUNPN with your requirements.

【20261105-XF】

 

Product Size Length: 640mm, Width: 430mm, Thickness: 50mm
Model No. YWB00093
Panel Material Acrylic organic glass + inkjet printing
Frame Material Black aluminum alloy outer frame
Display Material 3-inch digital tube (red light)
Data Storage Data retention for up to 7 days after power failure
Power Supply 220V, 1.8m cable, national standard three-pin plug
Installation Method Wall-mounted
Cable Outlet Aviation connector and network port on upper left of the screen
Accessories 25-key remote control *1, sound & light alarm *1, temperature sensor *1, differential pressure sensor *1

1. Three Critical Parameters, One Panel

Short claim: Temperature, dew point and differential pressure — monitored together, read at a glance.

Stop juggling separate thermometers and manometers. The YWB00093 shows all three cleanroom-critical parameters simultaneously in large 3-inch red LED digits — legible across the room, refreshed in real time, 24/7.

  • Simultaneous display: temperature (−20~100 °C), dew point (°C), differential pressure (Pa, negative values supported)
  • 3-inch high-brightness red digital tube, readable from meters away
  • Aluminum alloy housing + acrylic panel, wall-mounted, 640 × 430 mm
  • Bilingual (English/Chinese) or custom labels, OEM/ODM welcome

2. Alarms That Act, Calibration That Stays On Site

Short claim: Out-of-range in seconds, corrected in seconds — without a factory return.

Every parameter carries freely set upper and lower limits. When a value drifts, the buzzer sounds, the beacon flashes and the number flashes on screen — staff respond instantly. And with ±20.0 field error correction via remote control or host software, the readings always match your reference instrument.

  • Sound-light alarm: intermittent buzzer + flashing beacon + flashing value
  • ±20.0 error correction per parameter, set on site via 25-key remote or host software
  • 7-day power-off data storage — settings survive outages, no reconfiguration
  • Reminders cancellable remotely without clearing the flashing data prompt

3. Built to Connect — TCP/IP, RS485 and OkMes Integration

Short claim: Not just a signboard — a data node in your quality system.

With TCP/IP and RS485 over standard network port wiring, every reading flows into your BMS, SCADA or Environment Monitoring System Panel in real time. Scale from one room to the whole plant: boards networked through 200C gateways into the OkMes software for dashboards, alarm logs and exportable reports.

  • TCP/IP + RS485 communication, aviation plug and network port wiring
  • Plant-wide architecture: data boards → 200C gateways → LAN → database / software client / LCD terminal
  • OkMes software: real-time dashboards, abnormality logs, historical records and reports
  • Project supply support for multi-room and multi-site deployments

Recommend Products